Skip to content

ALTCER

Integration module

EMALTUS

EMAT measurement module for integration into a third-party aerial platform, delivered with a defined integration envelope and responsibility split.

EMALTUS

Discuss integration

1920 × 1080 EMALTUS in operation: real aircraft, sensor in contact with a coated steel surface Poster frame for the hero video. Real hardware, never CGI. One frame must show the contact point and the thickness value on the operator screen together. media placeholder
1920 × 1080 Hero video, 10-12 s Approach, contact, value on screen. Autoplay muted loop, no music, under 4 MB for web, separate 9:16 mobile crop. media placeholder
1.4 kg Module mass Sensor, mast and controller
22 – 26 V Input voltage DC, platform supplied
90 W Peak power During acquisition

Why the module exists

Demo narrative. Operators who already fly a certified platform need the measurement capability, not another aircraft. Every figure on this staging site is invented.

Integration

Integration Envelope

Integration envelope
Specification Value Condition Note
Module mass 1.4 kg no condition recorded Sensor, mast and controller
Physical envelope 180 × 140 × 120 mm no condition recorded Excluding mast travel
Mounting 4 × M4 no condition recorded 90 × 90 mm pattern
Input voltage 22 – 26 V no condition recorded DC
Peak current 4.0 A no condition recorded During acquisition
Communication UART, CAN no condition recorded Message set documented in the integration pack
Approach geometry ±20 deg no condition recorded Sensor to surface
Sensor positioning tolerance ±2 mm no condition recorded Platform hold accuracy required

Responsibility Matrix

Responsibility matrix
Integration area ALTCER Customer / integrator Notes
Mechanical mounting Supplies mounting pattern, mass and envelope data. Designs and certifies the mechanical interface.
Power States voltage and peak current. Provides conditioned power within the envelope.
Flight control Defines the hold accuracy the measurement needs. Achieves and verifies that hold accuracy. Positioning is the integrator responsibility.
Measurement data Provides the acquisition module and message set. Handles storage and downstream processing.
Airworthiness None. Owns platform certification and operational approval. ALTCER makes no airworthiness claim.
Specifications

Technical specifications

EMALTUS technical specifications
Specification Value Condition Note
Measurement system
Measurable thickness range 2 – 60 mm S355, lift-off up to 2 mm
Measurement accuracy 0.08 mm Reference block, lift-off 1 mm
Data
Data interface UART, CAN no condition recorded Documented message set

Documentation

EMALTUS integration pack

v2.1 · 2026-05-20 · EN

Sent by an engineer after a short qualification.

Request document

Discuss EMALTUS for your asset

Send the material, geometry and access constraints. You get a feasibility answer, including what is out of scope.